SMD LED, PLCC, white color, 3528, top view
Detailed Product Description
1.Description
size: 3.5*2.8*1.9
IV-Typ:1500mcd
IV-Max:1950mcd
Vf-Min:2.8V
Vf-Max:3.6V
If(mA):20
CIE: x:0.43 y:0.42
CCT: 2500-5000K
Viewing angle:120
2. Advantage:
LEDs offer many advantages over traditional light sources including 1ower power consumption, longer lifetime, smaller size, faster switching, and environmental friendliness.
Shinings LEDsapplications are diverse. They are used as Signal and Symbol Indicators, Illuminations (including Illuminated Advertising & General Lighting), LCD backlighting (including Netbooks, Notebooks, PDAs, and LED TVs), Indoor & Outdoor Displays,Automobile Interior Lighting, and Amusement Machines (including Slot Machines, Jack Pot, and Pachinko Machines).
3. Quality Assurance:
1>. All parts and products must be lead-free and RoHS compliant.
2> Shining's 6 Sigma system has been implemented to achieve a high quality standard and satisfy all customer needs.
3> Shining's quality monitoring system ensures high quality products & after service.
4. Reliability Testing System
NO. | Items | Testing Condition | Duration | No. of Damaged |
1 | Dc Operating Life | Ta=25 If=20mA | 1000hrs | 0/22 |
2 | High Temp.& High Humidity Life | Ta=85 RH=85% If=10mA | 500hrs | 0/22 |
3 | Low Temp. Life | Ta=40 If=20mA | 1000hrs | 0/22 |
4 | High Temp.& High Humidity Storage | Ta=85 RH=85% | 1000hrs | 0/22 |
5 | Low Temp. Storage | Ta=-40 | 1000hrs | 0/22 |
6 | Temperature Cycles | -40/100, 10min.dwell<15min.transfer> | 200Cycles | 0/22 |
7 | Thermal Shock | -40/100, 10min.dwell<10sec.transfer> | 200Cycles | 0/22 |
Criteria for Judging Damage
Item | Symbol | Condition | Criteria for Judgment | |
MIN | MAX | |||
Forward Voltage | VF | If=20mA | --- | USL×1.2 |
Reverse Current | IR | Vr=5V | --- | USL×2.0 |
Luminous Intensity | IV | If=20mA | LSL×0.7 | --- |
* USL: Upper Standard Level.
* LSL: Lower Standard Level.
5. Certificates